DSO5202BM Digital Storage Oscilloscope,2 Channels 200MHz 1GSa/s, 2M Record Length

FOB Reference Price:Get Latest Price
$459.00 - $519.00 / Piece | 1 Piece/Pieces (Min. Order)
Shipping:
Support Sea freight
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Guangdong, China
Brand Name:
Hantek
Model Number:
DSO5202BM
Digital Channels:
2
Band Width:
100-349MHz
Bandwidth:
200MHz
Real Time Sampling Rate:
1GSa/S
Sample Rate Range:
500MS/s--1GS/s
Supply Ability
Supply Ability:
1000 Piece/Pieces per Month
Packaging & Delivery
Packaging Details
Carton
Port
shenzhen
Lead Time :
Within 5 working days after successful payment

 

DSO5202BM Digital Storage Oscilloscope,2channels 200MHz 1GSa/s,  2M Record Length

1. Feature

200MHz bandwidths

1GSa/s Real Time sample rate

Large (7.0-inch) color display,WVGA(800x480)

Record length up to 2M

Trigger mode: edge/pulse width/line selectable video/slop/overtime etc.

USB host and device connectivity, standard

Multiple automatic measurements

Four math functions, including FFTs standard

Provides software for PC real-time analysis

VGA Optional

2. Specifications

ModelDSO5202BM
Acquisition
Sample RateReal-Time Sample: 1GS/s
Acquisition Modes 
NormalNormal data only
Peak DetectHigh-frequency and randon glith capture
AverageWavefom Average, selectable 4,8,16,32,64,128
Inputs
Inputs CouplingAC, DC, GND
Inputs Impendance1MΩ±2% 20pF±3pF
Probe Attenuation1X, 10X
Supported Probe Attenuation Factor1X, 10X, 100X, 1000X
Maximum Input VoltageCAT I and CAT II: 300VRMS (10×), Installation Category;
CAT III: 150VRMS (1×);
Installation Category II: derate at 20dB/decade above 100kHz to 13V peak AC at 3MHz* and above. For non-sinusoidal waveforms, peak value must be less than 450V. Excursion above 300V should be of less than 100ms duration. RMS signal level including all DC components removed through AC coupling must be limited to 300V. If these values are exceeded, damage to the oscilloscope may occur.
Horizontal System
Sample Rate Range500MS/s--1GS/s
Waveform Interpolation(sin x)/x
Record Length2M
SEC/DIV Range2ns/div to 40s/div
Sample Rate and
Delay Time Accuracy
±50ppm(at over any ≥1ms time interval)
Position Range2ns/div to 10ns/div;  (-4div x s/div) to 20ms;
Delta Time Measurement Accuracy 
(Full Bandwidth)
Single-shot, Normal mode:± (1 sample interval +100ppm × reading + 0.6ns);
>16 averages:± (1 sample interval + 100ppm × reading + 0.4ns);
Sample interval = s/div ÷ 200
Vertical System
Vertical Resolution8-bit resolution, all channel sampled simultaneously
Position Range2mV/div to 10V/div
Bandwidth200MHz
Rise Time at BNC( typical)1.8ns
Analog Bandwidth in Normal and Average modes at BNC or with probe, DC Coupled2mV/div to 20mV/div, ±400mV;  50mV/div to 200mV/div, ±2V
500mV/div to 2V/div, ±40V; 5V/div, ±50V
Math+, -, *, /, FFT
FFTWindows: Hanning, Flatop, Rectamgular, Bartlett, Blackman;
1024 sample point
Bandwidth Limit20MHz
Low Frequency Response (-3db)≤10Hz at BNC
DC Gain Accuracy±3% for Normal or Average acquisition mode, 5V/div to 10mV/div;
±4% for Normal or Average acquisition mode, 5mV/div to 2mV/div
DC Measurement Accuracy, 
Average Acquisition Mode
When vertical displacement is zero, and N ≥16:± (3% × reading + 0.1div + 1mV) only 10mV/div or greater is selected; 
When vertical displacement is not zero, and N≥16: ± [3% × (reading + vertical position) + 1% of vertical position + 0.2div]; Add 2mV for settings from 2mV/div to 200mV/div; add 50mV for settings from 200mV/div to 5V/div
Volts Measurement Repeatability, 
Average Acquisition Mode
Delta volts between any two averages of ≥16 waveforms acquired under same setup and ambient conditions
Trigger System
Trigger TypesEdge, Video, Pulse, Slope, Over time, Alternative
Trigger SourceCH1, CH2, EXT, EXT/5, AC Line
Trigger ModesAuto, Normal, Single
Coupling TypeDC, AC, Noise Reject, HF Reject, LF Reject
Trigger Sensitivity
(Edge Trigger Type)
DC(CH1,CH2):
1div from DC to 10MHz; 1.5div from 10MHz to 100MHz; 2div from 100MHz to Full;
DC(EXT): 
200mV from DC to 100MHz; 350mV from 100MHz to 200MHz;
DC(EXT/5):       
1V from DC to 100MHz;1.75V from 100MHz to 200MHz;       
AC: Attenuates signals below 10Hz;
HF Reject: Attenuates signals above 80kHz 
LF Reject: Same as the DC-coupled limits for frequencies above 150kHz; attenuates signals below 150kHz
Trigger Level RangeCH1/CH2: ±8 divisions from center of screen; 
EXT: ±1.2V;
EXT/5:±6V
Trigger Level Accuracy( typical)Accuracy is for signals having rise and fall times ≥20nsCH1/CH2: 0.2div × volts/div within ±4 divisions from center of screen;
EXT: ± (6% of setting + 40mV);
EXT/5: ± (6% of setting + 200mV);
Set Level to 50%(typical)Operates with input signals ≥50Hz

 

Our Services:

 

You May Like
Not exactly what you want? 1 request, multiple quotations Get Quotations Now >>
You May Like